120,000gals; 333gpm min turnover flowrate, VGB drains based on 1165rpm/1032gpm filtration and 1350gpm lazy river = 2382gpm max flow. Flowmeter added to features pump but flow is below ratings for meter? Recommend trying different flowmeter.
0.0
General Comments
Issued year round indoor pool permit with conditions!
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
Must have a National/ WCES CPO inspect pool at least once per day! Must post all CPO certificates in the pump room.
4.0
6.
2 minor typos were found that do not impact the actual installed pumps. Must have the corrections reviewed and submitted by a NC Design Professional within 30 days. Points taken but not closing!
6.0
16.
Lifeguarded pool with gate attendant. Emergency Exit door not working but repaired during the inspection. Points taken but not closing.
4.0
23.
Automatic cl/pH feeder functional
0.0
24.
120,000gals; 333gpm min turnover flowrate, VGB drains based on 1165rpm/1032gpm filtration and 1350gpm lazy river = 2382gpm max flow. Filtration 665gpm; Lazy river 925gpm; slide 550gpm; shallow features ~65gpm
0.0
General Comments
Pool reopened, issued year round indoor pool permit with conditions!
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
Must have a National/ WCES CPO inspect pool at least once per day! Must post all CPO certificates in the pump room.
4.0
6.
2 minor typos were found that do not impact the actual installed pumps. Must have the corrections reviewed and submitted by a NC Design Professional within 30 days. Points taken but not closing!
6.0
22.
Phone not functional. Alternative phone/line tried but address/ number did not match facility! This is a State and WCES 6pt closure item!
6.0
23.
Automatic cl/ pH feeder functional
0.0
24.
120,000gals; 333gpm min turnover flowrate, VGB drains based on 1165rpm/1032gpm filtration and 1350gpm lazy river = 2382gpm max flow. Lazy river 905gpm; slide 550gpm; shallow features 75-80gpm
0.0
General Comments
Pool closed and posted closed by management. Pool must remain closed until all 6pt closure items are corrected and a reinspection by WCES is completed and the pool is reopened. Please call 919.604.4302 to schedule the reinspection once all 6pt closure items are corrected to schedule the reinspection.
Repair broken flowmeter on current channel and slide. Need to install flowmeter on shallow feature pump. All meters must be functional at permitting! 120,000gals; 333gpm min turnover flowrate, VGB drains based on 1165rpm/1032gpm filtration and 1350gpm lazy river = 2382gpm max flow
0.0
25.
Store all chemicals off the floor by 12inches.
0.0
General Comments
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
Verified VGB certification. 333gpm min turnover flowrate based on 120,000gal
0.0
24.
533gpm/1165rpm filtration, 780gpm/1185rpm lazy river for total 1313gpm; 400gpm/1750rpm slide, need to add flow meter to feature. Max flow on filtration pump 1165rpm/1775rpm x 1000gpm = 656gpm
0.0
General Comments
Issued year round indoor pool permit with conditions!
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
Must show when pool is closed and reopened due to chemical being off!
0.0
6.
VGB drains must be replaced and certification submitted and approved prior to permitting before reopening after closure starting 2/14/22! Need additional flow meters added to assist with VGB certification. Points taken but not closing!
6.0
23.
Automatic cl/pH feeder functional
0.0
24.
~1013gpm final setting for max flow. Variable speed pumps were operating higher than allowed under previous VGB certification. Speed lowered during the inspection. Points taken but not closing!
4.0
General Comments
Issued modified pool permit with conditions!
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
Do not let CPO certificates expire! Post all CPO certificates in the pump room!
0.0
6.
Must replace VGB drains and have recertifications submitted and approved prior to permitting in 2022. If Skimmer equalizer covers are installed, recommend removing skimmer equalizer covers and permanently plugging both ends of the skimmer equalizer ports.
0.0
8.
Repair covers to allow access and keep clean.
4.0
9.
Need depth markers on surface deck between shallow splash area. Will check to see if required.
0.0
16.
Lifeguarded pool with gate attendant.
0.0
General Comments
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
Lifeguarded pool with gate attendant. Still keep eye on emergency exit doors.
0.0
18.
Lifeguarded pool at all times.
0.0
24.
No imminent hazard found. Have an electrician evaluate all of the components to determine function.
0.0
General Comments
Issued year round indoor pool permit.
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
This pool must remain closed until the local and state closure orders currently in effect as a result of the COVID-19 pandemic are terminated.
Pool staff and patrons are strongly encouraged to comply with the most current CDC guidance concerning social distancing related to the COVID-19 pandemic.
Must take readings 7 days a week 6hrs apart. This can be a WCES 6pt closure item. Records have greatly improved, but still have a few days missing.
4.0
16.
Lifeguarded pool with gate attendant. Still need to verify doors are selfclosing/latching. Especially emergency exit doors! This can be a WCES 6pt closure item and can prevent permit from being issued!
4.0
18.
Lifeguards must be on duty at all times or sign must be posted indicating No Lifeguard On Duty.
0.0
24.
No imminent hazard found. Have an electrician evaluate all of the components to determine function.
0.0
General Comments
This inspection was entered in error on wrong ID# on 12-9-20 and recreated on this record on 12-15-20. Originally signed by the CPO and the report sent to him using the wrong ID #.
Indoor year round pool.
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
This pool must remain closed until the local and state closure orders currently in effect as a result of the COVID-19 pandemic are terminated.
Pool staff and patrons are strongly encouraged to comply with the most current CDC guidance concerning social distancing related to the COVID-19 pandemic.
Need to keep at least 6 months of records on site. Recommend sending digital copy or duplicates to central office.
0.0
15.
Lifeguarded pool.
0.0
16.
Lifeguarded pool with gate attendant.
0.0
General Comments
Issued year round pool permit. Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
Lifeguard pool with "gate attendant". Recommend keeping self latching doors latched.
0.0
General Comments
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
Emergency telephone did not work properly. Emergency telephone replaced on site. Some skimmer baskets are floating on surface of water. Make sure all staff know how to properly test pool ph and chlorine levels and how to record them.