The hand sinks in the men's restroom are 117F and the women's restroom is 115F. The water temperature for lavatories shall not exceed 110F.
2.0
General Comments
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
Fence quote was finalized yesterday. New fence being replaced in ~ 2 weeks. Plexi-glass was connected to area of fence where a car hit it since bowed gap was 4.5 inches. Vertical rungs were added to bottom to meet 2" clearance.
0.0
General Comments
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
At beginning of inspection, pH of water was around 8-9. Before finishing inspection, concentration of Ph was brought to proper requirements.
0.0
7.
Slight debris in bottom of pool.- Please vacuum pool to keep clean.
4.0
General Comments
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
The flow meter is not working.- Flow meter shall be operating properly.
4.0
General Comments
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
This pool must remain closed until the local and state closure orders currently in effect as a result of the COVID-19 pandemic are terminated.
No night swimming.
Pool staff and patrons are strongly encouraged to comply with the most current CDC guidance concerning social distancing related to the COVID-19 pandemic.
Pool Chlorine was 0.0ppm- Pool chlorine shall be at least 1
6.0
3.
The pH was 7.0.- Pool water pH must be 7.2 to 7.8.
6.0
16.
The fence is heavily damaged on one side making an opening in the fence more than 4" apart.- Fence shall be maintained in good condition and the gaps may be no more than 4".
4.0
22.
The phone did not have a dial tone.- Emergency telephone shall be provided and working properly.- Please repair phone.
6.0
24.
The flow meter is not working.- Flow meter shall be operating properly.
4.0
General Comments
Permit NOT issued today. Pleas pay reinspection fee of $75 and we can reschedule
Emergency telephone would not ring when EHS tried to call it. CPO went and got a new phone that works before inspection was finished.
0.0
General Comments
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form. NO NIGHT SWIMMING
There are items other than chemicals or equipment in the chemical and equipment rooms. Chemical and pool equipment rooms should only be used for specific pool chemical and pool equipment storage.
0.0
General Comments
The emergency phone information was all corrected according to 911 system but the address was not showing up in the 911 system as a swimming pool. Recommend contacting telephone service provider about updating the telephone information. All 3 entrance gates have required signage posted upon entering, however it is recommended to add a couple more No Diving sign on the pool deck as an added precaution.