Score: 4

#  Comments Points
16. Upon arrival, towel bins on fence edge served as a foot hold, but these items were relocated. Gate on opposite side of main entrance is to be locked at all times. 4.0
17. Deck drain missing a very small piece on left side of deep end if standing at main entrance. 0.0
24. Flow meter registering at 110gpm. 0.0
General Comments
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.

No night swimming.
Red Denotes Critical Violation
View Last 3 Inspections for this Establishment

Hampton Inn Pool
Location: 1050 S Main ST HOLLY SPRINGS, NC 27540
Facility Type: Seasonal Swimming Pools
Inspection Date: 05/23/2023
Score: 0

#  Comments Points
6. VGB info field verified. 0.0
24. Flow meter reading 110gpm. 0.0
General Comments
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.

No night swimming.
Red Denotes Critical Violation
View Last 3 Inspections for this Establishment

Hampton Inn Pool
Location: 1050 S Main ST HOLLY SPRINGS, NC 27540
Facility Type: Seasonal Swimming Pools
Inspection Date: 05/26/2022
Score: 0

#  Comments Points
24. Flow meter observed at 80gpm. Max flow rate on VGB letter is 130gpm. 0.0
General Comments
Pool volume is 14,880 gallons. Hayward SP3210EE pump listed on VGB letter verified in pump room. Hayward WG1032BHF drain covers listed on VGB letter verified onsite. Paramount SDX Retro equalizer covers listed on VGB letter verified onsite. No SVRS. Visible areas of bonding wire observed in good condition. Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form. CPO certificates are required to be provided onsite at all times; recommend keeping certificates with the pool maintenance book. No night swimming.
Red Denotes Critical Violation
View Last 3 Inspections for this Establishment

Hampton Inn Pool
Location: 1050 S Main ST HOLLY SPRINGS, NC 27540
Facility Type: Seasonal Swimming Pools
Inspection Date: 06/09/2021
Score: 4

#  Comments Points
16. Can access gate release latch through bars of gate. Gate shall have no openings greater than 0.5 inch within 18 inches of the release mechanism. Corrected at time of inspection by screwing plexiglass to gate to cover openings. 4.0
General Comments
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.

No recipient signature due to covid restrictions.

No night swimming.
Red Denotes Critical Violation
View Last 3 Inspections for this Establishment

Hampton Inn Pool
Location: 1050 S Main ST HOLLY SPRINGS, NC 27540
Facility Type: Seasonal Swimming Pools
Inspection Date: 05/27/2021
Score: 10

#  Comments Points
5. CPO only has Wake County operator certification. National certification is expired. 4.0
15. Ring buoy rope longer than 1 1/2 the width of the pool. Rope was shortened top proper length. 6.0
General Comments
Facility does not have a CPO with both Wake County and National Certification. Permit not issued. Go to https://www.wakegov.com/departments-government/environmental-health-and-safety/public-swimming-pools for instructions on paying reinspection fee. Email a copy of the receipt to karla.crowder@wakegov.com to schedule reinspection.
Red Denotes Critical Violation
View Last 3 Inspections for this Establishment

Hampton Inn Pool
Location: 1050 S Main ST HOLLY SPRINGS, NC 27540
Facility Type: Seasonal Swimming Pools
Inspection Date: 11/23/2010
Score: 0

#  Comments Points
General Comments
The SIPS# for this pool has changed since the pool no longer has a heater. See 530833 for history of this pool.
Red Denotes Critical Violation
View Last 3 Inspections for this Establishment


Keyword (1):
Keyword (2):
Keyword (3):
Score Range:
-
Establishment Type:
Zipcode:
Violations:
Date Range:
- - Start
- - End

Health Inspections Home :: FAQ